← CVE index
Vulnerability record/PUBLISHED/Published Nov 10, 2026 20:08:12 UTC

CVE-2026-120809

A use-after-free read issue exists in MongoDB’s SBE (Slot-Based Execution) engine when processing aggregation pipelines with $unwind on time-series collections. An internal error in state-preservation logic can cause a value still referenced by downstream stages to have its underlying memory freed prematurely. An authenticated user can craft an aggregation pipeline under specific conditions to trigger this condition, potentially reading recycled server heap memory in query results or crashing the server. This issue is only triggerable when a non-default server parameter related to the SBE engine is enabled.

Base score6.1/ 10
SeverityMediumCVSS 4.0

Exploitability / impact

CVSS metric breakdown

Vector-derived attributes
Base severityMedium
Attack vectorNetworkAV
Attack complexityLowAC
Attack requirementsPresentAT
Privileges requiredLowPR
User interactionNoneUI
Vulnerable system confidentialityHighVC
Vulnerable system integrityNoneVI
Vulnerable system availabilityHighVA
Subsequent system confidentialityNoneSC
Subsequent system integrityNoneSI
Subsequent system availabilityNoneSA
CVSS vector stringCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS communicates standardized severity and impact characteristics. It does not establish whether a system is exploitable in your specific environment.

Record context

CVE Numbering Authoritymongodb
Last updatedNov 13, 2026 19:42:43 UTC
PublishedNov 10, 2026 20:08:12 UTC
ReservedNov 2, 2026 22:54:19 UTC