D-Link – G integrated Access Device4 Information Disclosure & Authorization Bypass.
*Information Disclosure –
file contains a URL with private IP at line 15 "login.asp" A. The
window.location.href = http://192.168.1.1/setupWizard.asp" http://192.168.1.1/setupWizard.asp" ;
"admin" – contains default username value "login.asp" B. While accessing the web interface, the login form at
*Authorization Bypass –
URL by "setupWizard.asp' while it blocks direct access to – the web interface does not properly validate user identity variables values located at the client side, it is available to access it without a "login_glag" and "login_status" checking browser and to read the admin user credentials for the web interface.